R407f Pt Chart
It should be noted that R407F does have a higher discharge temperature so demand cooling may be required. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407A (psig)*. Chart For 61 Freons (R410A, R134A, R22, etc. R407C Pressure-Temperature Chart Liquid. It can be used in new equipment and can replace R-22, R-404A, R-507, and R-407A in existing equipment. R407F Pressure Temperature Chart R407F Pressure Temperature Chart R407F Pressure Temperature Chart The information contained within this website is for guidance only,. This is one of the most commonly used low GWP refrigerants. R407F, Blend, HFC. R407F Pressure Temperature Chart R407F Pressure Temperature Chart R407F Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. Show details Fill pressure temperature chart: Try Risk Free Form Popularity r438a refrigerant pt chart form Get, Create, Make and Sign pt chart Get Form eSign Fax Email Add Annotation r438a Pressure Chart is not the form youre looking for? Search for another form here. At the low end, the pressure of 404A is 0. R407F, Blend, HFC. R407F is a viable lower GWP option albeit only a temporary solution. R407F is a viable lower GWP option albeit only a temporary solution. Use for low and medium temperature commercial refrigeration, plug ins, and vending applications. R407F Pressure Temperature Chart 14 9. Regardless of what your thoughts on R-407F you will need to know the pressures and temperatures in order to properly maintenance it. R407A, Blend, HFC. In this video, you’ll learn how to use the app by comparing two refrigerants, R407F and R507. Like R404A, R407F is a HFC refrigerant and a POE lubricant will be required. R407F Pressure Enthalpy Chart. Refrigerants: National™ R-407F Looking for something else? Choose a Refrigerant Product Information This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications. R507A has a 3,985 GWP R1234yf has a 4 GWP. HFC blend with significantly lower GWP than R404A, suitable for low and medium temperature applications. R407F Pressure Temperature Chart. Just check the R404A PT chart below and you will see that the pressure of 404A liquid at 85°F is 189. (R-407F) This new refrigerant is an HFC blend containing forty percent of R-134a, thirty percent of R-125, and thirty percent of R-32. Name: R407A: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 82. If the lubricant is contaminated or an acid test indicates high levels of acidity, then a lubricant change is required. 8) + 32Dew Point(Saturated vapour), used to determine superheat Bubble Point(Saturated liquid), used to determine subcooling PRESSURE TEMPERATURE CHART PRESSURE kPa GAUGE (# Unless otherwise indicated, all pressures shown are saturated vapour pressures). PDF Forane Refrigerant Pressure Temperature Chart. HFC refrigerant widely used for medium temperature and auto A/C applications. See our short video guide to r448a. At the high end, the pressure of 404A is 456. Genetron® PerformaxTM LT, R407F Thermodynamic Properties. PT CHART FOR GENETRON PERFORMAX® LT. R407F: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 79. The pressure enthalpy chart in Figure 2 shows the critical point and the extent of the transcritical fluid region. R407A, R407F, R448A and R449A have a temperature glide between 3K and 6K. Figure 2: Pressure enthalpy chart for R744 A significant challenge with the application of CO 2 as a refrigerant is the higher operating pressures compared to other commercial refrigerants. We are, of course, talking about 404A liquid pressure. Well known for its relatively easy retrofit process. R407F has a GWP of 1,824 making it less than half that of R404A, F-Gas compliant, similar cooling capacity and improved efficiency. R404A to R407F RETROFIT PROCEDURE Whilst R407F is a good match for R404A, check OEM recommendations to ensure the existing systems design is suitable, including system capacities, relief valve sizing and equipment seal material compatibility. Pressure Temperature Chart: R-407F. R404A to R407F RETROFIT PROCEDURE Whilst R407F is a good match for R404A, check OEM recommendations to ensure the existing systems design is suitable, including system capacities, relief valve sizing and equipment seal material compatibility. If you were using 1,000 pounds of R-22, you’ll need about 938 pounds of R-407F, as follows:Pounds of R-407F = 1,000 x 69. R407a, r407f, r448a, r449a pressure temperature chart. R407f Pt ChartR407F R407F Temperature (°C) Liquid Pressure (kPa) Liquid Pressure bar Vapor Pressure (kPa) Vapor Pressure (bar) Liquid Density (kg/m³) Vapor Density (kg/m³) Liquid Volume (m³/kg) Vapor Volume (m³/kg) iquid Internal Energy (kJ/kg) Vapor Internal Energy (kJ/kg) Liquid Enthalpy (kJ/kg) Vapor Enthalpy (kJ/kg) -60,15 48,3 0,483 32,5 0,325 1415,17 1,53. Read about the advantages of R407A and R407F to lower the GWP in commercial refrigeration systems, and learn about retrofitting existing R404A systems. Pt Chart / R134a Refrigerant Pressure >R448A Refrigerant Pt Chart / R134a Refrigerant Pressure. Best for use in: This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications and is used as a. R-407F Refrigerant PT Chart January 19, 2020 by Alec Johnson One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or. United Refrigeration Inc. Honeywell Genetron Refrigerants P. R22 R134a R404A R414B R507))))) 44)) – – – –)) – – – HOW TO CHECK SUPERHEAT Example: Refrigerant 134a Suction Temperature TECUMSEH MODEL CHART AE AG. (R-407F) This new refrigerant is an HFC blend containing forty percent of R-134a, thirty percent of R-125, and thirty percent of R-32. For capacities correction factors for thermostatic expansion. PDF TEMPERATURE PRESSURE CHART. R407F is a viable lower GWP option albeit only a temporary solution. SDS/MSDS: Honeywell. P-h Chart Download - Metric Units. Polyolester lubricant in use with R404A/R507 is suitable for use with R407A, R407F, R448A and R449A. TEMPERATURE PRESSURE CHART. Forane® Refrigerant Pressure Temperature Chart PRESSURE (PSIG) Sat. R407F. PDF REFRIGERANT CHANGEOVER HFC R404A OR R507 TO HFC R407A, R407F. Vapor: Liquid: Vapor Liquid: Vapor Liquid: Vapor-49; 0; 8. R407F Pressure Temperature Chart R407F Pressure Temperature Chart R407F Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. These four types make up 90% of the Refrigerant market. R404A to R407F RETROFIT PROCEDURE Whilst R407F is a good match for R404A, check OEM recommendations to ensure the existing systems design is suitable, including system capacities, relief valve sizing and equipment seal material compatibility. 9 Scan to learn more about our new PT Chart. Box 1053Morristown, New Jersey 07962-1053For more information call us at 1-800-631-8138 or visit us at www. Forane 404A Pressure Temperature Chart Forane 404A, R-404A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas. 9; Saturation Pressure-Temperature Data for R407C (psig)* Temp. R407C Pressure-Temperature Chart Liquid. Name: R407F: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 79. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R404A (psig)*. Like R404A, R407F is a HFC refrigerant and a POE lubricant will be required. Honeywell Genetron Refrigerants P. In this video, you’ll learn how to use the app by comparing two refrigerants, R407F and R507. Make your job easier with our handy refrigerant pressure temperature HVAC app with R-407F included. R407F Pressure Temperature Chart R407F Pressure Temperature Chart R407F Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. PT CHART FOR GENETRON® 407C New Pressure-based Charts Make Calculating Glide Easier Refrigerants SUPERHEAT Procedure: • Use gauges to determine the pressure at. As a retrofit, Opteon™ XP40 offers: Improved performance Similar capacity Significant GWP reduction: 67% lower GWP than R-404A and R-507, 33% lower GWP than R-407A and 30% lower GWP than R-22. Forane 407C Pressure Temperature Chart Forane 407C, R-407C, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas. Temp(°F) R-22 R-407C LiquidPressure R-407C VaporPressure R-410A LiquidPressure R-427A. Measurements R-407F Oil Type: POE Critical Temperature: 180. Saturation Pressure-Temperature Data for R-407A (psig)* Forane 407A Pressure Temperature Chart Forane 407A, R-407A, Pressure Temperature Chart, PT Chart,. Genetron Performax® LT (R-407F) / European Refrigerants Genetron Performax ® LT (R-407F) Home / Products / Genetron Performax ® LT (R-407F) Replacement for R-22 and R-404A in supermarket retrofits or new supermarket refrigeration systems with best combination of lowest GWP and energy efficiency. The cooling capacity is similar to that of R404A and has a lower discharge temperature than R22. In 2009 the Honeywell corporation invented a new refrigerant called Genetron Performax. (R-407F) This new refrigerant is an HFC blend containing forty percent of R-134a, thirty percent of R-125, and thirty percent of R-32. A refrigerant replacement for R22 & R404A systems and is well known for its relatively easy retrofit process. Measurements R-407F Oil Type: POE Critical Temperature: 180. R407F Temperature (°C) Liquid Pressure (kPa) Liquid Pressure bar Vapor Pressure (kPa) Vapor Pressure (bar) Liquid Density (kg/m³) Vapor Density (kg/m³) Liquid Volume (m³/kg) Vapor Volume (m³/kg) iquid Internal Energy (kJ/kg) Vapor Internal Energy (kJ/kg) Liquid Enthalpy (kJ/kg) Vapor Enthalpy (kJ/kg)-60,15. Refrigerant option for low and medium temperature in commercial refrigeration. P-h Chart Download – Metric Units. The refrigerant came into the. R407F Pressure Temperature Chart 14 9. Make your job easier with our handy refrigerant pressure temperature HVAC app. The refrigerant came into the market as a retrofit replacement for R404A and R22. GWP for R407F from supplier’s data. National Refrigerants Ltd>R23. LT (R-407F) Replacement for R-22 and R-404A in supermarket retrofits or new supermarket refrigeration systems with best combination of lowest GWP. Forane 404A Pressure Temperature Chart Forane 404A, R-404A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas. PT – Chart R407C>Refrigerant Guys PT – Chart R407C. R448A Refrigerant Pt Chart / R134a Refrigerant Pressure. Facts and Prices of Refrigerants (R134a and R410a and more). R-407F – Hudson Technologies Type: HFC Chemical Name or Components: R-134a (40%), R-32 (30%), R-125 (30%) 1,1,1,2-Tetrafluoroethane, Difluoromethane, Pentafluoroethane SDS/MSDS: Honeywell Pressure Temperature Chart: R-407F. Forane® Refrigerant Pressure Temperature Chart PRESSURE (PSIG) Sat. R407F: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 79. Retrofitting systems that employ compressors manufactured prior to 1973 is not recommended. 06 bara GWP: 1824 Safety Class: A1 CAS Number: 75-10-5/354-33-16/811-97-2 Color Code: Green-Yellow-White373 Molecular Mass: 82. (R-407F) This new refrigerant is an HFC blend containing forty percent of R-134a, thirty percent of R-125, and thirty percent of R-32. Make your job easier with our handy refrigerant pressure temperature HVAC app with R-407F included. Record baseline data on original system R404A/R507 performance. HVAC Buddy® Charging & Diagnostic Pressure Temperature. This non-ozone depleting, hydrofluorocarbon (HFC) refrigerant is a replacement for R-22 and provides a lower global warming potential (GWP) alternative to R-404A and R-507. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. 5 psig and the pressure of 404A vapor is 187. It is very rarely used nowadays. Common Alternative: R-22, R-404A. PDF PT CHART FOR GENETRON 407C. R407F Pressure Enthalpy Chart. Refrigerant Guys PT – Chart R407C. Scroll down to download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. This page shows log P/h diagrams for the following refrigerants: R22 R134a R404A R407C R410A R717 (Ammonia) R744 (Carbon dioxide) R507 R22 R134a R404A R407C R410A R717 R744 R507. The cooling capacity is similar to that of R404A and has a lower. Forane Refrigerant Pressure Temperature Chart. R407C, Blend, HFC. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. 9 Scan to learn more about our new PT Chart. That will save a significant amount of money versus having to purchase an entirely new system. Forane 407A Pressure Temperature Chart Forane 407A, R-407A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas. 5 POE = polyol ester, MO = mineral oil, AB = Alkylbenzene ** Divide by 7. PT CHART FOR GENETRON® 407C New Pressure-based Charts RefrigerantsMake Calculating Glide Easier Temperature GENETRON® 407C (R-407C)PRESSURE BASED PT CHART Temperature Charge Calculation POE = polyol ester, MO = mineral oil, AB = Alkylbenzene ** Divide by 7. Refrigerant Changeover Guidelines HFC R. Refrigerant GWP Chart For 61 Freons (R410A, R134A, R22, etc. Pressure Temperature Chart. Forane® Refrigerant Pressure Temperature Chart PRESSURE (PSIG) Sat. R407F has a GWP of 1,824 making it less than half that of R404A, F-Gas compliant, similar cooling capacity and improved efficiency. Temperature Tecumseh Model Number - Refrigerant Code °F °C R22 (E) R134a (Y) R290 (U) R404A (Z) R407C (C) R407F R410A (B) R414B/ Hot Shot R438A/ MO99. Gas2Go Pressure Temperature Chart ANZ 0317. R-407F Refrigerant PT Chart Showing 1 to 71 of 71 entries. As long as you have a fully sealed cylinder and there are no leaks on the cylinder you refrigerant will last indefinitely. The thinking behind this refrigerant was to come up with a viable alternative to the currently used R-404A in supermarkets. Download Pressure Temp Chart (PDF) Download Pressure Enthalpy Chart (PDF) Download Safety Data Sheet (PDF) R134a. Forane® Refrigerant Pressure Temperature Chart PRESSURE (PSIG) Sat. Honeywell Genetron RefrigerantsP. Temperature°C = (°F - 32) ÷ 1. Temperature Tecumseh Model Number - Refrigerant Code °F °C R22 (E) R134a (Y) R290 (U) R404A (Z) R407C (C) R407F R410A (B) R414B/ Hot Shot R438A/ MO99. Scan to learn more about calculating Glide. 06 C R-407F Charging & Diagnostic HVAC Buddy®. R407A is a Hydrofluorocarbon refrigerant blend that consists of three components: R134A (40%), R125 (40%), and R32 (20%). Scroll down to download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and. R407F R407F Temperature (°C) Liquid Pressure (kPa) Liquid Pressure bar Vapor Pressure (kPa) Vapor Pressure (bar) Liquid Density (kg/m³) Vapor Density (kg/m³) Liquid Volume (m³/kg) Vapor Volume (m³/kg) iquid Internal Energy (kJ/kg) Vapor Internal Energy (kJ/kg) Liquid Enthalpy (kJ/kg) Vapor Enthalpy (kJ/kg) -60,15 48,3 0,483 32,5 0,325 1415,17 1,53. The thinking behind this refrigerant was to come up with a viable alternative to the currently used R-404A in supermarkets and grocers across the world today. Name: R407C: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 81. R407a, r407f, r448a, r449a pressure temperature chart. R407F Thermodynamic Properties >Genetron® PerformaxTM LT, R407F Thermodynamic Properties. Capacities of thermostatic expansion valves with R407A/F will be approximately 10% larger than the capacity for R22. R407C has a 1,774 GWP. In 2009 the Honeywell corporation invented a new refrigerant called Genetron Performax. These charts were provided courtesy of Danfoss, using their FREE CoolSelector 2 software. R-407F – Hudson Technologies Type: HFC Chemical Name or Components: R-134a (40%), R-32 (30%), R-125 (30%) 1,1,1,2-Tetrafluoroethane, Difluoromethane, Pentafluoroethane SDS/MSDS: Honeywell Pressure Temperature Chart: R-407F. Freon™ 407A (R-407A) refrigerant is a reliable, stable, and nonflammable option for low- and medium-temperature refrigeration systems. com>R407F Pressure Temperature Chart. Common Alternative: R-22, R-404A Container Sizes (lbs. PT Chart Refrigerant Replacements Refrigerants and Legislation Technical Literature Products and Services HFC’s HFO’s Lower GWP Alternatives Natural Refrigerants Aerosol Service Gases Environmental Services Lab Services News Contact Product Information Back To Products Refrigerant Gases - HFCs R23 GWP: 14,800IPCC 4th Revision. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 1. Make your job easier with our handy refrigerant pressure temperature HVAC app with R-407F included. Name: R407F: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 79. If you were using 1,000 pounds of R-22, you’ll need about 938 pounds of R-407F, as follows:Pounds of R-407F = 1,000 x 69. R407F Pressure Enthalpy Chart. PT CHART FOR GENETRON® 407C New Pressure-based Charts RefrigerantsMake Calculating Glide Easier Temperature GENETRON® 407C (R-407C)PRESSURE BASED PT CHART Temperature Charge Calculation POE = polyol ester, MO = mineral oil, AB = Alkylbenzene ** Divide by 7. Get r438a pt chart Form and fill it out in March 2023. PT Chart Refrigerant Replacements Refrigerants and Legislation Technical Literature Products and Services HFC’s HFO’s Lower GWP Alternatives Natural Refrigerants Aerosol Service Gases Environmental Services Lab Services News Contact Product Information Back To Products Refrigerant Gases - HFCs R23 GWP: 14,800IPCC 4th Revision. PT charts for the zeotropic blends list two columns next to each temperature: one for the saturated liquid (bubble point) and the other for the saturated vapor (dew point). R407F Temperature (°C) Liquid Pressure (kPa) Liquid Pressure bar Vapor Pressure (kPa) Vapor Pressure (bar) Liquid Density (kg/m³) Vapor Density (kg/m³). PT Chart: Pressure Temperature Chart For. 9 lbs/ft 3: Liquid Density at 80°F: 69. 06 C R-407F Charging & Diagnostic HVAC Buddy®. There are four primary types Refrigerant that you will run into R-12, R-22, R-134A, and R-410A. R407F Pressure Temperature Chart 14 9. R-407F - Hudson Technologies Type: HFC Chemical Name or Components: R-134a (40%), R-32 (30%), R-125 (30%) 1,1,1,2-Tetrafluoroethane, Difluoromethane, Pentafluoroethane SDS/MSDS: Honeywell Pressure Temperature Chart: R-407F. R407A Refrigerant Facts & Info Sheet. This is a table that tells you precisely what the pressure of R404A is at a certain temperature. R407F Pressure Enthalpy Chart. You can download that software free of charge also using this link. Appendix B - Log P/h diagrams for refrigerants The log P/h diagrams on this page can be retrieved from the Coolpack program, which can be downloaded here. Comments and Help with r407f pt chart. 0 lbs/ft 3: Liquid Density at 80°F. Cha rt>Pressure – Temperatur e Cha rt. Box 1053 Morristown, New Jersey 07962-1053 For more information call us at 1-800-631-8138 or visit us at www. R407A Pressure-Temperature Chart Liquid. Forane® Refrigerant Pressure Temperature Chart PRESSURE (PSIG) Sat. This is due to the different materials used in motor insulation systems that have not been evaluated for compatibility with. You’ll also get a walkthrough of all the different functions you can perform in the app and see the information you can get about each refrigerant, including class, GWP, ODP, superheat, and more. 9 lbs/ft 3: Liquid Density at 80°F. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! Refrigerants - Pressure vs. Pressure Temperature Chart: R-407F. Does Refrigerant Go Bad? No, refrigerant will not go bad. Some of the zeotropic blends have very low glide (from 1˚F to 2. PT CHART FOR GENETRON® 407C New Pressure-based Charts RefrigerantsMake Calculating Glide Easier Temperature GENETRON® 407C (R-407C)PRESSURE BASED PT CHART Temperature Charge Calculation POE = polyol ester, MO = mineral oil, AB = Alkylbenzene ** Divide by 7. We use gauge meter to measure the pressure of R404A refrigerant at different temperatures. R407A is a Hydrofluorocarbon refrigerant blend that consists of three components: R134A (40%), R125 (40%), and R32 (20%). R407F has a GWP of 1,824 making it less than half that of R404A, F-Gas compliant, similar cooling capacity. )>Refrigerant GWP Chart For 61 Freons (R410A, R134A, R22, etc. Refrigerants: National™ R-407F Looking for something else? Choose a Refrigerant Product Information This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications. *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407A (psig)*. LT (R-407F) Replacement for R-22 and R-404A in supermarket retrofits or new supermarket refrigeration systems with best combination of lowest GWP and energy efficiency. Appendix B - Log P/h diagrams for refrigerants The log P/h diagrams on this page can be retrieved from the Coolpack program, which can be downloaded here. / Refrigeration & HVAC Replacement. One of the very first steps when it comes to diagnosing your home air conditioner, refrigerator, or even your vehicle’s air conditioner is understanding the temperature and the current pressure that your system is operating at. Name: R407C: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 81. R-407F Refrigerant PT Chart. Name: R407A: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 82. You’ll also get a walkthrough of all the different functions you can perform in the app and see the information you can get about. Pressure Temperature Chart ANZ 0317>Gas2Go Pressure Temperature Chart ANZ 0317. Pressure Temperature Chart: R-407F Best for use in: This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications and is used as a replacement for R22 & R404A systems. R407F Temperature (°C) Liquid Pressure (kPa) Liquid Pressure bar Vapor Pressure (kPa) Vapor Pressure (bar) Liquid Density (kg/m³) Vapor Density (kg/m³). Genetron Performax. In this video, you’ll learn how to use the app by comparing two refrigerants, R407F and R507. R404A PT Chart: Pressure Temperature Chart For. Pressure Temperature Chart: R-407F. Scroll down to download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. R407F: Type: Blend: Class: HFC: Lubricant: POE: Liquid Density at 0°F: 79. Genetron® PerformaxTM LT, R407F Thermodynamic …. 404R pressure temperature chart is quite simple to understand. Rating conditions & displayed performances according to reference standard. Vapor: Liquid: Vapor Liquid: Vapor Liquid: Vapor-49; 1. Best for use in: This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications and is used as a replacement for R22 & R404A systems. PDF R407F Pressure Temperature Chart. R407F Pressure Temperature Chart R407F Pressure Temperature Chart R407F Pressure Temperature Chart The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly. CO2 as a Refrigerant — Properties of R744. Pressure – Temperatur e Cha rt. R22 R134a R404A R414B R507))))) 44)) - - - -)) - - - HOW TO CHECK SUPERHEAT Example: Refrigerant 134a Suction Temperature TECUMSEH MODEL CHART AE AG AH AJ AK AN AV AW AZ RG RK SA SF TP HG TH TW VS = R22 = R134a = R404A = R507 AA AB XA XC XN) Tecumseh Products Company. REFRIGERANT CHANGEOVER HFC R404A OR R507 TO …. Product Information This zeotropic blend can be used in low and medium-temperature commercial refrigeration applications. R407F Pressure Enthalpy Chart. Freon™ 407A (R-407A) refrigerant is a reliable, stable, and nonflammable option for low- and medium-temperature refrigeration systems. It should be noted that R407F does have a higher discharge temperature so demand cooling may be required. Pressure Temperature Chart: R-407F. The refrigerant with the highest GWP is R23 with 12,400 GWP. R407A, R407F, R448A, R449A pressure temperature chart R407A, R407F, R448A or R449A refrigerant 1. Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Talk with the developers of HVAC Buddy® and 1,000s of other HVAC professionals and hobbyists that use our apps. Just check the R404A PT chart below and you will see that the pressure of 404A liquid at 85°F is 189. R407A is a Hydrofluorocarbon refrigerant blend that consists of three components: R134A (40%), R125 (40%), and R32 (20%). These charts were provided courtesy of Danfoss, using their FREE CoolSelector 2 software. Download honeywell pt chart ruler. Measurements R-407F Oil Type: POE Critical Temperature: 180. Temp(°F) R-22 R-407C LiquidPressure R-407C VaporPressure R-410A LiquidPressure R-427A LiquidPressure R-427A VaporPressure R-407A LiquidPressure R-407A VaporPressure R-123 R-12 R-134a -506. PT charts for the zeotropic blends list two columns next to each temperature: one for the saturated liquid (bubble point) and the other for the saturated vapor (dew point). R407F Pressure Enthalpy Chart. PT CHART FOR GENETRON 407C. Saturation Pressure-Temperature Data for R-407C (psig)* Forane 407C Pressure Temperature Chart Forane 407C, R-407C, Pressure Temperature Chart, PT Chart,.